Skip to content
1-888-777-2966info@monoglass.com
MonoglassMonoglass
Monoglass
Monoglass Spray Applied Insulations

Spray Applied Thermal & Acoustic Insulation Products
Insulating your world since 1979

  • Products
    • Monoglass Spray-On Insulation
    • Sonoglass Acoustic Treatment
    • Insulseal Protective Coating
    • Color Spray Tints
    • Monoglass Spray Nozzle
  • Home
  • Projects
    • Project Spotlight
    • International Projects
    • North American Projects
  • Information
    • Environment and LEED
    • Material Safety Data Sheets
    • Sound Rating Guides
    • Test Data and Specs
    • Continuing Education Credits
  • Product News
  • Information for Applicators
  • Contact Us
    • Contact Us
    • Opportunities
  • Products
    • Monoglass Spray-On Insulation
    • Sonoglass Acoustic Treatment
    • Insulseal Protective Coating
    • Color Spray Tints
    • Monoglass Spray Nozzle
  • Home
  • Projects
    • Project Spotlight
    • International Projects
    • North American Projects
  • Information
    • Environment and LEED
    • Material Safety Data Sheets
    • Sound Rating Guides
    • Test Data and Specs
    • Continuing Education Credits
  • Product News
  • Information for Applicators
  • Contact Us
    • Contact Us
    • Opportunities

Sound Rating Guides

  • Steel Frame Drywall Partition
  • Steel Joist Ceiling
  • Wood Frame Drywall Partition
  • Wood Joist Ceiling

Sound Rating Guide SF

Steel Frame Drywall Partition
CodeFramingFacingSound Transmission Coefficient
SF 51 5/8" studs at 16" o.c.5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.46
SF 101 5/8" studs at 24" o.c.2 layers 1/2" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.55
SF 15 2 1/2" studs at 24" o.c.1/2" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.47
SF 20 2 1/2" studs at 24" o.c.5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.51
SF 25 2 1/2" studs at 24" o.c.2 layers 1/2" drywall one side, 1 layer 1/2" drywall other side and 1.5" Monoglass Spray-On between studs, one side.52
SF 30 2 1/2" studs at 24" o.c.2 layers 5/8" drywall one side, 1 layer 5/8" drywall other side and 1.5" Monoglass Spray-On between studs, one side.54
SF 35 2 1/2" studs at 24" o.c.2 layers 5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.57
SF 40 3 5/8" studs at 24" o.c.1/2" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.48
SF 45 3 5/8" studs at 24" o.c.5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.50
SF 50 3 5/8" studs at 24" o.c.2 layers 1/2" drywall one side, 1 layer 1/2" drywall other side and 1.5" Monoglass Spray-On between studs, one side.53
SF 55 3 5/8" studs at 24" o.c.2 layers 5/8" drywall one side, 1 layer 5/8" drywall other side and 1.5" Monoglass Spray-On between studs, one side.54
SF 60 3 5/8" studs at 24" o.c.2 layers 1/2" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.55
SF 65 3 5/8" studs at 24" o.c.2 layers 5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.56

View the complete Sound Rating Guide in PDF format here:

  • Monoglass Sound Rating Guide STC charts

Sound Rating Guide SJ

Steel Joist Ceiling
CodeJoist & FloorFacingSound Transmission Coefficient
SJ 512" steel joists 6 lb./ft. at 24" o.c. 2" - 3000 PSI concrete floor5/8" drywall on drywall furing channel at 24" o.c. and 1" Monoglass Spray-On to concrete slab ceiling.49
SJ 1012" steel joists 6 lb./ft. at 24" o.c. 2" - 3100 PSI concrete floor1/2" drywall on drywall furing channel at 24" o.c. and 1" Monoglass Spray-On to concrete slab ceiling.48
SJ 1510" steel joists 4.8 lb./ft. at 24" o.c. 2 1/2" - 4000 PSI concrete floor1/2" drywall on drywall furing channel at 24" o.c. and 1" Monoglass Spray-On to concrete slab ceiling.50
SJ 2012" steel joists 6 lb./ft. at 24" o.c. 2" - 3500 psi concrete floor2 layers 5/8" drywall on nailing channel at 24" o.c. and 1" Monoglass Spray-On to concrete slab ceiling.50
SJ 25Hambro steel joists 10" deep 5.5 lb./ft. min. 2.5" or 3.5" - 3500 PSI concrete floor, air duct, firestop flap, electrical outlets.51/2" drywall on drywall furing channel at 24" o.c. and 1" Monoglass Spray-On to concrete slab ceiling.55

View the complete Sound Rating Guide in PDF format here:

  • Monoglass Sound Rating Guide STC charts
Click to enlarge
Steve Nash Fitness Club

Sound Rating Guide WF

Wood Frame Drywall Partition
CodeFramingFacingSound Transmission Coefficient
WF 52 rows 2 x 3 studs 1" apart at 16" o.c.5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.49
WF 102 x 4 studs at 16" o.c.2 layers 1/2" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.45
WF 152 x 4 studs at 16" o.c.2 layers 5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.48
WF 20Staggered 2 x 4 studs at 8" o.c. on 2" x 6" plate5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.51
WF 25Staggered 2 x 4 studs at 8" o.c. on 2" x 6" plate2 layers 1/2" drywall both sides and 1.5" Monoglass Spray-On between studs, one side.54
WF 30Staggered 2 x 4 studs at 8" o.c. on 2" x 6" plate2 layers 5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side56
WF 352 rows 2 x 4 studs 1" apart at 16" o.c.5/8" drywall both sides and 1.5" Monoglass Spray-On between studs, one side52

View the complete sound rating guide in PDF format here:

  • Monoglass Sound Rating Guide STC charts

Sound Rating Guide WJ

Wood Joist Ceiling
CodeCeiling JoistFacingSound Transmission Coefficient
WJ 52 X 8 joists at 16" o.c.1/2" drywall and 1.5" Monoglass Spray-On between joists and drywall resilient channel.45
WJ 102 X 8 joists at 16" o.c.5/8" drywall and 1.5" Monoglass Spray-On between joists and drywall resilient channel.46
WJ 152 X 8 joists at 16" o.c.2 layers 1/2" drywall and 1.5" Monoglass Spray-On between joists and drywall resilient channel.50
WJ 202 X 10 joists at 16" o.c.1/2" drywall and 1.5" Monoglass Spray-On between joists and drywall resilient channel.47
WJ 252 X 10 joists at 16" o.c.5/8" drywall and 1.5" Monoglass Spray-On between joists and drywall resilient channel.48
WJ 302 X 10 joists at 16" o.c.2 layers 1/2" drywall and 1.5" Monoglass Spray-On between joists and drywall resilient channel.53
WJ 352 X 10 joists at 16" o.c.2 layers 5/8" drywall and 1.5" Monoglass Spray-On between joists and drywall resilient channel.54

View the complete Sound Rating Guide in PDF format here:

  • Monoglass Sound Rating Guide STC charts
Share this page
Monoglass Products Video
https://monoglass.com/wp-content/uploads/2017/11/Promo-Video1.mp4
Monoglass Newsletter
Sign-up form

Please enter your email address to subscribe:

Recent Posts & News
  • MasterSpec : New On-Line Listings for Monoglass and Sonoglass products
    February 5, 2019
  • B.C. Family Day Monday February 18th – Office Closure
    February 2, 2019
  • cold weather monoglass
    Cold Weather Warnings & Tips
    November 29, 2018
wordpress visitor
Contact Us
Monoglass Incorporated
1200 West 73rd Avenue, #922
Vancouver, B.C. Canada
V6P 6G5
Telephone: (604) 261-7712
Toll-Free in North America:
1-888-777-2966
1-888-SPRAY-ON
Fax: (604) 261-1342
E-mail: info@monoglass.com
Email Us

Submitclear

Recent Posts & News
  • MasterSpec : New On-Line Listings for Monoglass and Sonoglass products
    February 5, 2019
  • B.C. Family Day Monday February 18th – Office Closure
    February 2, 2019
  • cold weather monoglass
    Cold Weather Warnings & Tips
    November 29, 2018
  • The Fall Rush is here, along with colder temperatures.
    November 2, 2018
Monoglass Upcoming Events
<
< 2017 >
February
>
List
Month
List
Week
Day
  • 13

    BC Family Day Office Closure

    https://monoglass.com/event/bc-family-day-office-closure/
    All day
    17-02-13

    It’s Family Day on Monday February 13th, 2017 and our office will be closed for the day.

Monoglass
Copyright Monoglass Incorporated 2017. All rights reserved. Monoglass and Sonoglass are registered trademarks of Monoglass Incorporated.
  • Contact Us
bottom